# AI in healthcare: where it is used, what trials show, and the rules

AI in healthcare is software that learns from data to draft clinical notes, read images, score risk, answer reference questions and process insurance requests. In the American Medical Association's 2026 survey, [72% of US physicians said they currently use at least one AI use case](https://www.ama-assn.org/system/files/physician-ai-sentiment-report.pdf) (read 12 November 2026), and the [FDA's public list](https://www.fda.gov/medical-devices/artificial-intelligence-enabled-medical-devices/list-artificial-intelligence-enabled-medical-devices) held 1,614 authorized AI-enabled devices (read 22 November 2026).

The trial evidence is mixed. Randomized trials show modest time savings from AI scribes and higher cancer detection in mammography screening, and several large trials of triage, stethoscope and deterioration tools found no benefit on their primary outcome.

By Ulsa Editorial. Updated 22 November 2026

On this page

- Where AI is used in healthcare
- What the evidence shows
- Adoption figures and what each one counts
- The rules, with dates
- Where the evidence conflicts

## Where AI is used in healthcare

### Clinical documentation: ambient AI scribes

An ambient AI scribe is software that listens to a visit and drafts the clinical note for the clinician to review. In a randomized trial of 238 physicians at UCLA, [one scribe product cut time in notes by 9.5% and the other showed no significant change](https://ai.nejm.org/doi/full/10.1056/AIoa2501000) (NEJM AI, 26 November 2025, read 12 November 2026).

[Epic released its built-in ambient note tool, AI Charting](https://www.epic.com/epic/post/epic-ai-charting-rolls-out-alongside-an-expanding-set-of-built-in-ai-capabilities/), in the first week of February 2026, and [Microsoft said in March 2026](https://www.microsoft.com/en-us/microsoft-cloud/blog/healthcare/2026/03/05/unify-simplify-scale-microsoft-dragon-copilot-meets-the-moment-at-himss-2026/) that more than 100,000 clinicians use Dragon Copilot in daily practice. Both are company figures without a definition of active use.

### Medical imaging

The largest trial on this page is in imaging. In the Swedish MASAI randomized trial of 105,934 women, [AI-supported mammography screening had higher sensitivity (80.5% against 73.8%) and a non-inferior interval cancer rate](https://www.thelancet.com/journals/lancet/article/PIIS0140-6736(25)02464-X/abstract) compared with standard double reading (The Lancet, 31 January 2026, read 12 November 2026).

On 17 September 2026 the FDA [refused a petition](https://www.federalregister.gov/documents/2026/09/17/2026-19074/medical-devices-exemption-from-premarket-notification-radiology-computer-aided-detection-andor) to partly exempt radiology computer-aided detection, diagnosis and triage software from 510(k) review. Radiology AI software therefore still needs premarket notification in the United States.

### Deterioration and sepsis

Predictive AI is software that classifies a patient or produces a risk score, for example for readmission or early disease detection. ASTP/ONC reports that [71% of US non-federal acute care hospitals used predictive AI integrated with the electronic health record in 2024](https://healthit.gov/data/data-briefs/hospital-trends-use-evaluation-and-governance-predictive-ai-2023-2024/), up from 66% in 2023 (read 12 November 2026).

The 2026 randomized evidence in this area is thin. A randomized trial of an AI deterioration-risk display on an 85-bed US cardiology ward [found no improvement in patient outcomes](https://pubmed.ncbi.nlm.nih.gov/41644641/) across 10,422 inpatient visits. In sepsis care, a cluster-randomized trial at two UC San Diego emergency departments tested feedback written by a large language model on compliance with the SEP-1 sepsis bundle: [compliance was 82.9% with feedback and 70.1% without](https://pubmed.ncbi.nlm.nih.gov/42348212/), with no significant difference in intensive care admissions or 30-day mortality. That trial tested quality-measure feedback, and it did not test sepsis prediction. Both PubMed records were read 22 November 2026.

### Prior authorization

Medicare's WISeR model uses AI and machine learning with human clinical review for prior authorization of selected services in Traditional Medicare. [WISeR runs in six states from 1 January 2026 to 31 December 2031](https://www.cms.gov/priorities/innovation/innovation-models/wiser), and CMS says every recommendation for non-payment is determined by a licensed clinician (read 22 November 2026).

CMS records released by the Electronic Frontier Foundation on 8 September 2026 describe [a request left unanswered for 83 days against a 72-hour target, and 5,944 requests denied by two vendors in the first three months](https://www.eff.org/deeplinks/2026/09/new-records-reveal-problems-medicares-ai-prior-authorization-experiment). In the AMA's prior authorization survey of 1,000 physicians, [six in 10 were concerned that AI may raise denial rates](https://www.ama-assn.org/press-center/ama-press-releases/ama-survey-prior-authorization-reform-pledge-falls-short-physicians); the press release does not give the exact percentage.

### What is the most common AI in healthcare?

No single source ranks every kind of AI in healthcare. In the American Medical Association's 2026 survey of US physicians, the most common use was summaries of medical research and standards of care (39%), followed by drafting discharge instructions, care plans and progress notes (30%) and billing codes, charts and visit notes (28%). Among US hospitals, 71% reported predictive AI integrated with the electronic health record in 2024, according to ASTP/ONC.

The AMA figures come from a multi-select question about 17 named use cases, answered by 1,342 physicians in the 2026 wave. The hospital figure counts predictive AI only and does not measure generative AI or scribes. The FDA device list page does not state a share by specialty, so this site does not print one.

### Is there a medical AI like ChatGPT?

Yes. OpenEvidence is an AI clinical information platform for verified clinicians: a JAMA analysis published on 15 October 2026 counted 952,008 US clinicians who submitted 271 million queries between 1 January 2024 and 30 June 2026. OpenAI launched ChatGPT Health for consumers on 7 January 2026 and ChatGPT for Healthcare for health systems on 8 January 2026, and Anthropic introduced Claude for Healthcare in January 2026.

Use is not the same as accuracy. In an Oxford-led randomized study of 1,298 members of the public, [people using large language models did no better than a control group](https://pubmed.ncbi.nlm.nih.gov/41663592/) at identifying conditions or choosing where to seek care (Nature Medicine, February 2026). On 20 November 2026 the GAO reported that [the FDA had not authorized any chatbot for mental health care](https://www.gao.gov/products/gao-27-109184). All three sources were read 22 November 2026.

## What the evidence shows

The table lists trials with their design, size and main result as the journal abstract states them. A trial marked "null" did not meet its primary outcome.

Trials and studies of AI in clinical care. PubMed records read 22 November 2026; the UCLA and MASAI records read 12 November 2026.

| Study | Design | n | Result | Source |
| --- | --- | --- | --- | --- |
| Ambient AI scribes, UCLA | Three-group pragmatic randomized trial | 238 physicians | Time in notes: Nabla -9.5% (95% CI -17.2% to -1.8%; P=0.02); DAX Copilot -1.7% (95% CI -9.4% to +5.9%; P=0.66) | [NEJM AI, 26 Nov 2025](https://ai.nejm.org/doi/full/10.1056/AIoa2501000) |
| Ambient AI scribes, University of Wisconsin | 24-week stepped-wedge, individually randomized pragmatic trial | 66 practitioners | Work exhaustion -0.44 points (95% CI -0.62 to -0.25); time on notes -0.36 hours per day (95% CI -0.55 to -0.17); professional fulfillment +0.14 points, reported as nonsignificant | [NEJM AI, Dec 2025](https://pubmed.ncbi.nlm.nih.gov/41625485/) |
| Heidi AI scribe, 14-hospital Boston system | Retrospective quality improvement study, interrupted time series | 902 clinicians | Note-active time -1.21 minutes (95% CI -1.74 to -0.68); no differences in same-day closure, after-hours closure or work RVUs | [Ann Intern Med, Nov 2026](https://pubmed.ncbi.nlm.nih.gov/42932880/) |
| MASAI mammography screening, Sweden | Randomized, controlled, non-inferiority, single-blinded trial | 105,934 women | Interval cancers 1.55 against 1.76 per 1,000 (proportion ratio 0.88, 95% CI 0.65 to 1.18); sensitivity 80.5% against 73.8% (p=0.031) | [The Lancet, 31 Jan 2026](https://www.thelancet.com/journals/lancet/article/PIIS0140-6736(25)02464-X/abstract) |
| AI triage in mammography, Spain | Prospective paired non-inferiority trial | 31,301 women | Radiologist workload 63.6% lower; cancer detection 15.2% higher (95% CI 6.6% to 24.4%); recall rate 14.8% higher and not noninferior | [Nat Med, Apr 2026](https://pubmed.ncbi.nlm.nih.gov/41857202/) |
| LungIMPACT chest X-ray prioritization, UK | Multicenter randomized controlled trial | 93,326 chest X-rays | Null. Median time to CT 53 days in both arms (ratio 0.97, 95% CI 0.93 to 1.02; P=0.31) | [Nat Med, May 2026](https://pubmed.ncbi.nlm.nih.gov/41876649/) |
| TRICORDER AI stethoscope, UK | Cluster-randomized implementation trial | 205 GP practices | Null. Heart failure detection incidence rate ratio 0.94 (95% CI 0.86 to 1.02) | [The Lancet, 14 Feb 2026](https://pubmed.ncbi.nlm.nih.gov/41619752/) |
| AI deterioration-risk display, US cardiology ward | Pragmatic cluster-randomized trial | 10,422 inpatient visits | Null. No improvement in patient outcomes; the abstract gives no effect size | [Sci Rep, 5 Feb 2026](https://pubmed.ncbi.nlm.nih.gov/41644641/) |
| LLM feedback on sepsis bundle compliance, UC San Diego | Single-blind cluster-randomized trial | 66 physicians, 301 patients | SEP-1 compliance 82.9% against 70.1% (odds ratio 2.10, 95% CI 1.15 to 3.81); no difference in intensive care admissions or 30-day mortality | [JAMA Netw Open, 1 Jun 2026](https://pubmed.ncbi.nlm.nih.gov/42348212/) |
| LLM decision support in primary care, Kenya | Pragmatic cluster-randomized trial | 9,691 patients | Null. Treatment failure within 14 days 2.2% against 2.0% (adjusted odds ratio 0.77, 95% CI 0.55 to 1.08; P=0.13) | [Nat Med, Aug 2026](https://pubmed.ncbi.nlm.nih.gov/42362867/) |
| LLMs as medical assistants for the public, Oxford-led | Preregistered randomized study with scenarios | 1,298 participants | Participants using LLMs identified relevant conditions in fewer than 34.5% of cases, no better than control; the LLMs alone identified them in 94.9% | [Nat Med, Feb 2026](https://pubmed.ncbi.nlm.nih.gov/41663592/) |
| Automation bias with wrong LLM suggestions, Pakistan | Single-blind randomized trial | 44 physicians | Diagnostic reasoning accuracy 73.3% against 84.9% in control (adjusted difference -14.0 percentage points, 95% CI -18.9 to -9.1) | [NEJM AI, May 2026](https://pubmed.ncbi.nlm.nih.gov/42932681/) |

Two things stand out in these abstracts. Time savings from AI scribes are measured in minutes per note or fractions of an hour per day. In the Spanish screening trial, the gain in cancer detection arrived together with a higher recall rate.

## Adoption figures and what each one counts

Adoption figures for AI in healthcare differ because each survey counts something different. The table gives the definition next to each number.

Adoption of AI in US healthcare by measure. Sources read 22 November 2026, except the AMA survey and ASTP/ONC Data Brief 80, read 12 November 2026.

| Figure | Who and when | What it counts | Source |
| --- | --- | --- | --- |
| 72% (AMA headline: 81%) | 1,692 US physicians, fielded 15 January to 2 February 2026 | 72% currently incorporate one or more of 17 named AI use cases. The 81% headline is "awareness or use" and adds 9% who are unsure which AI tools their practice offers | [AMA physician survey](https://www.ama-assn.org/system/files/physician-ai-sentiment-report.pdf) |
| 71% | US non-federal acute care hospitals, 2024 | Predictive AI integrated with the electronic health record | [ASTP/ONC Data Brief 80](https://healthit.gov/data/data-briefs/hospital-trends-use-evaluation-and-governance-predictive-ai-2023-2024/) |
| 52.2% | 2,174 US non-federal acute care hospitals, 2024 | Predictive AI in the analytic sample of a journal study; a different definition and denominator from Data Brief 80 | [JAMA Network Open, 12 Dec 2025](https://jamanetwork.com/journals/jamanetworkopen/fullarticle/2842683) |
| 31.5% | The same 2,174 hospitals, 2024 | Generative AI integrated with the electronic health record. A further 24.7% planned to adopt within a year | [JAMA Network Open, 12 Dec 2025](https://jamanetwork.com/journals/jamanetworkopen/fullarticle/2842683) |
| 42% | 550 US healthcare executives, September 2026 | Organizations that say they have implemented healthcare-specific AI tools. Vendor survey by a venture firm | [Menlo Ventures](https://menlovc.com/perspective/2026-the-state-of-ai-in-healthcare/) |
| 952,008 clinicians | Verified US accounts, 1 January 2024 to 30 June 2026 | Clinicians who used one AI clinical information platform, OpenEvidence; data from the platform | [JAMA, 15 Oct 2026](https://pubmed.ncbi.nlm.nih.gov/42879271/) |
| 32% | 1,343 US adults, fielded 24 February to 2 March 2026 | Used an AI chatbot for health information in the past year | [KFF](https://www.kff.org/health-information-trust/poll-1-in-3-adults-are-turning-to-ai-chatbots-for-health-information-equaling-the-share-who-use-social-media-for-health/) |
| 34% | 3,488 US adults, fielded 22 to 28 June 2026 | Have ever used an AI chatbot for at least one of eight health purposes | [Pew Research Center](https://www.pewresearch.org/science/2026/08/25/from-diagnoses-to-treatments-why-americans-use-ai-chatbots-for-health/) |

## The rules, with dates

US rules for AI in healthcare are split between the FDA (devices), CMS (payment), ASTP/ONC (health IT certification) and the states. This page is information for professionals and is not legal advice.

Federal and international rules that apply to AI in healthcare, with status and dates. Regulator pages read 22 November 2026.

| Body | Rule or action | Status and dates | Source |
| --- | --- | --- | --- |
| FDA | Guidance on lifecycle management and marketing submissions for AI-enabled device software functions | Draft, published January 2025. Not finalized as of 22 November 2026 | [FDA guidance page](https://www.fda.gov/regulatory-information/search-fda-guidance-documents/artificial-intelligence-enabled-device-software-functions-lifecycle-management-and-marketing) |
| FDA | Guidance on predetermined change control plans for AI-enabled device software functions | Final. Guidance page last modified 18 August 2025 | [FDA guidance page](https://www.fda.gov/regulatory-information/search-fda-guidance-documents/marketing-submission-recommendations-predetermined-change-control-plan-artificial-intelligence) |
| FDA | Discussion paper on regulating generative AI-enabled medical devices | For discussion only. Feedback closed 19 October 2026 | [FDA discussion paper](https://www.fda.gov/medical-devices/digital-health-center-excellence/considerations-regulation-generative-ai-enabled-medical-devices-discussion-paper-and-request) |
| CMS | WISeR model: AI-assisted prior authorization in Traditional Medicare | Six states, 1 January 2026 to 31 December 2031 | [CMS Innovation Center](https://www.cms.gov/priorities/innovation/innovation-models/wiser) |
| CMS | Interoperability and Prior Authorization final rule (CMS-0057-F) | Decisions within 72 hours (expedited) or seven calendar days (standard) from 1 January 2026; API requirements generally from 1 January 2027. The rule covers process and does not itself regulate AI | [CMS fact sheet](https://www.cms.gov/newsroom/fact-sheets/cms-interoperability-prior-authorization-final-rule-cms-0057-f) |
| CMS | CY 2027 hospital outpatient final rule (CMS-1850-F) | Issued 4 November 2026. Renames the category to "Software as a Medical Service" and pays through New Technology APCs as an interim step | [CMS fact sheet](https://www.cms.gov/newsroom/fact-sheets/calendar-year-2027-hospital-outpatient-prospective-payment-system-opps-ambulatory-surgical-center-0) |
| AMA | CPT 2027 code set | 10 new AI codes, 43 AI-related codes in total, effective 1 January 2027. A CPT code does not by itself mean a payer covers the service | [AMA release](https://www.ama-assn.org/press-center/ama-press-releases/ama-releases-cpt-2027-code-set) |
| ASTP/ONC | HTI-5 final rule | Released by HHS 26 October 2026; published in the Federal Register 28 October 2026; effective 28 December 2026, some instructions 1 January 2027. Removes 14 certification criteria, including the AI model card source-attribute requirements set by HTI-1 | [Federal Register](https://www.federalregister.gov/documents/2026/10/28/2026-21943/health-data-technology-and-interoperability-onc-deregulatory-actions-to-unleash-prosperity) |
| European Union | AI Act after the AI Omnibus | Omnibus in force 27 July 2026. High-risk rules for Annex III uses apply from 2 December 2027, and for AI embedded in Annex I regulated products from 2 August 2028. The Commission pages read do not name medical devices | [AI Act Service Desk](https://ai-act-service-desk.ec.europa.eu/en/ai-act/timeline/timeline-implementation-eu-ai-act) |
| United Kingdom | National Commission into the Regulation of AI in Healthcare | Report 10 September 2026; government accepted all 44 recommendations on 6 October 2026; MHRA draft guidance on changes to AI-enabled devices due by December 2026 | [GOV.UK](https://www.gov.uk/government/news/government-backs-recommendations-of-nhs-doctors-led-ai-commission) |

### US state laws

State laws on AI in care and in mental health chatbots. Legislature and governor pages read 22 November 2026.

| State and law | What it requires | Date |
| --- | --- | --- |
| [California AB 3030](https://leginfo.legislature.ca.gov/faces/billNavClient.xhtml?bill_id=202320240AB3030) | A disclaimer on patient clinical communications generated by generative AI, with instructions for reaching a human | Approved 28 September 2024 |
| [California SB 1120](https://leginfo.legislature.ca.gov/faces/billNavClient.xhtml?bill_id=202320240SB1120) | Requirements for health plans and insurers that use AI or algorithms in utilization review | Approved 28 September 2024 |
| [California AB 489](https://leginfo.legislature.ca.gov/faces/billNavClient.xhtml?bill_id=202520260AB489) | AI systems may not use terms that imply their advice comes from a licensed health professional | Approved 11 October 2025 |
| [California AB 1979 and SB 503](https://www.gov.ca.gov/2026/09/30/californias-nation-leading-ai-framework-just-got-stronger-governor-newsom-signs-more-first-in-the-nation-worker-protections-and-more/) | Providers may use their own judgment when AI informs care; developers of clinical decision tools must take reasonable steps to reduce known or predictable bias | Signed 30 September 2026; effective 1 January 2027 according to the California Health Care Foundation |
| [Texas HB 149](https://capitol.texas.gov/tlodocs/89R/billtext/html/HB00149F.htm) | Health care providers disclose AI use to the patient no later than the date of first service | Effective 1 January 2026 |
| [Texas SB 1188](https://capitol.texas.gov/tlodocs/89R/billtext/html/SB01188F.htm) | Practitioners may use AI for diagnostic purposes if they review AI-created records and disclose the use to patients | Effective 1 September 2025 |
| [Illinois HB 1806](https://www.ilga.gov/Legislation/BillStatus?DocNum=1806&GAID=18&DocTypeID=HB&SessionID=114&GA=104) | Licensed professionals may not let AI make independent therapeutic decisions in therapy; civil penalty up to $10,000 | Effective 1 August 2025 |
| [Nevada AB 406](https://www.leg.state.nv.us/App/NELIS/REL/83rd2025/Bill/12575/Overview) | AI providers may not offer systems programmed to provide professional mental or behavioral health care | Effective 1 July 2025 |
| [Utah HB 452](https://le.utah.gov/~2025/bills/static/HB0452.html) | Disclosure and data-use rules for mental health chatbots | Effective 7 May 2025 |
| [New York chatbot law](https://www.governor.ny.gov/news/governor-hochul-signs-nation-leading-legislation-protect-kids-ai-chatbots-and-ensure-baby) | Bars unsafe chatbot features for minors; penalties up to $25,000 per violation | Signed 28 October 2026; effective date not given in the release |

Federal policy may limit state AI laws. [Executive Order 14365 of 11 December 2025](https://www.whitehouse.gov/presidential-actions/2025/12/eliminating-state-law-obstruction-of-national-artificial-intelligence-policy/) set up a Justice Department task force to challenge state AI laws and called for a federal framework that preempts conflicting ones, with a carve-out for child safety. The order does not mention health care, and no enacted federal preemption statute was found when the sources were read on 22 November 2026.

## Where the evidence conflicts

**Physician use of AI**

The AMA's 2026 report gives 72% for physicians who currently use at least one named use case and 81% for "awareness or use". The 81% figure includes 9% who are unsure which AI tools their practice offers. The 2026 wave also includes partial responses, so comparisons with 48% in 2024 and 38% in 2023 are approximate.

**Hospital use of predictive AI**

ASTP/ONC Data Brief 80 reports 71% of hospitals in 2024. A JAMA Network Open study of the same survey year reports 52.2% in its analytic sample. The two use different definitions and denominators.

**Public use of chatbots for health**

KFF reports 32% in the past year and 29% at least monthly. Pew reports 34% ever and, in an earlier survey, 22% at least sometimes. The four figures measure four different things.

**Do AI scribes save time or raise billing**

Randomized and observational studies find small reductions in note time. Two observational studies also found slightly higher billing: at UCSF, adopters billed 1.81 more RVUs per week (95% CI 0.86 to 2.75), and at Providence, ambient AI use was followed by 7.40 more RVUs per month (95% CI 0.80 to 14.00). The 14-hospital Boston study found no change in work RVUs.

**Deskilling in colonoscopy**

A 2025 Polish observational study reported that adenoma detection without AI fell from 28.4% to 22.4% after endoscopists had been using AI. A 2026 prospective trial of 13 endoscopists and 5,013 colonoscopies found no deskilling and no lasting learning after AI was removed. The designs and outcome measures differ.

**AI draft replies to patient messages**

At Columbia, rollout of an AI draft-reply tool was associated with 8.6% longer turnaround overall, although messages answered with the tool were 29.5% faster. At UC San Diego Health, all 15 categories of physician edit to AI drafts were linked to longer response times.

**HTI-5 dates**

HHS released the HTI-5 final rule on 26 October 2026. The Federal Register published it on 28 October 2026. Both dates are correct for different events.

**EU AI Act and medical devices**

The Commission pages give 2 August 2028 for AI embedded in Annex I regulated products and name machinery, toys and lifts as examples. The pages read do not name medical devices, so this site does not state a device-specific date as confirmed.

## Healthcare is one of the 14 industries Ulsa covers

Ulsa is an app that reads hundreds of sources across 14 industries, groups the articles about the same thing into one story, and tells you what changed in AI and how much it matters for your work.

Free: a feed fitted to one or two sentences you write about your work, refreshed every 24 hours, and every industry's edition.

[Open Ulsa](https://ulsa.ai/?utm_source=aiinhealthcarenews.com&utm_medium=satellite&utm_campaign=healthcarenews&utm_content=ai-in-healthcare)

---

Source: https://aiinhealthcarenews.com/ai-in-healthcare/
Updated: 2026-11-22
Publisher: Ulsa sp. z o.o. (https://ulsa.ai)
Language: en

AI disclosure: the text and figures on this site were prepared with AI tools from the cited sources. Ulsa sp. z o.o. is responsible for the content. Report an error: hello@ulsa.ai.